SICK西克
C40E-1503CA010產(chǎn)品詳細(xì)信息:
| receiver | |||||||||||||||||||||||||||
| Type | C40E-1503CA010 | ||||||||||||||||||||||||||
| Part No. | 1018652 | ||||||||||||||||||||||||||
| sender | |||||||||||||||||||||||||||
| Type | C40S-1503CA010 | ||||||||||||||||||||||||||
| Part No. | 1018651 | ||||||||||||||||||||||||||
At a glance
Your benefits
| |||||||||||||||||||||||||||
| Functions-Sender | |||
| Beam coding: | ![]() | ||
| Reduced resolution: | - | ||
| Configuration method: | PC with CDS (Configuration and Diagnostic Software) | ||
| Extension connection: | - | ||
| PSDI mode with: | UE402 | ||
| Safe SICK device communication via EFI/SDL: | ![]() | ||
| Functions-Receiver | |||
| Restart interlock: | ![]() | ||
| Restart interlock (delivery status): | external | ||
| External device monitoring (EDM): | ![]() | ||
| External device monitoring (delivery status): | deactivated | ||
| Beam coding: | ![]() | ||
| Beam coding (delivery status): | non-coded | ||
| Reduced resolution: | - | ||
| Bypass (with UE402): | ![]() | ||
| Emergency stop / bypass at extension connection: | - | ||
| Operating mode switching (with UE402): | ![]() | ||
| PSDI mode with: | UE402 | ||
| Muting with: | Flexi Classic | ||
| Configuration method: | PC with CDS (Configuration and Diagnostic Software) | ||
| Extension connection: | - | ||
| Safe SICK device communication via EFI/SDL: | ![]() | ||
| Technical Data-Sender | |||
| Protective field height: | 1,500 mm | ||
| Resolution: | 30 mm | ||
| Housing length: | 1,632 mm | ||
| Housing cross-section: | 48 mm x 40 mm | ||
| Type: | Type 4 (IEC 61496) | ||
| Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) | ||
| Category: | category 4 (EN ISO 13849) | ||
| Performance level: | PL e (EN ISO 13849) | ||
| PFHd: | 1.5 * 1E-08 | ||
| TM (mission time): | 20 a | ||
| Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC | ||
| Connection type: | Hirschmann plug M26 x 11 + FE, straight | ||
| Connection type configuration connection: | M8 x 4 | ||
| Maximum connection cable cross-section: | 0.75 mm2 | ||
| Wave length: | 950 nm | ||
| Protection class: | III (EN 50178) | ||
| Enclosure rating: | IP 65 (EN 60529) | ||
| Ambient operating temperature: | 0 °C ... 55 °C | ||
| Vibration resistance (checked to): | 5 g (IEC 60068-2-6) | ||
| Oscillation frequency from ... to: | 10 Hz ... 55 Hz | ||
| Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) | ||
| Weight: | 3,110 g | ||
| Technical Data-Receiver | |||
| Protective field height: | 1,500 mm | ||
| Resolution: | 30 mm | ||
| Scanning range from ... to: | 0 m ... 19 m | ||
| Scanning range from ... to (delivery status): | 0 m ... 6 m | ||
| Housing length: | 1,632 mm | ||
| Housing cross-section: | 48 mm x 40 mm | ||
| Type: | Type 4 (IEC 61496) | ||
| Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) | ||
| Category: | category 4 (EN ISO 13849) | ||
| Performance level: | PL e (EN ISO 13849) | ||
| PFHd: | 1.5 * 1E-08 | ||
| TM (mission time): | 20 a | ||
| Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC | ||
| Response time without beam coding: | ≤ 14 ms | ||
| Response time with beam coding: | ≤ 24 ms | ||
| Maximum switching current: | 500 mA | ||
| Wave length: | 950 nm | ||
| Connection type: | Hirschmann plug M26 x 11 + FE, straight | ||
| Connection type configuration connection: | M8 x 4 | ||
| Maximum connection cable cross-section: | 0.75 mm2 | ||
| Protection class: | III (EN 50178) | ||
| Enclosure rating: | IP 65 (EN 60529) | ||
| Ambient operating temperature: | 0 °C ... 55 °C | ||
| Vibration resistance (checked to): | 5 g (IEC 60068-2-6) | ||
| Oscillation frequency from ... to: | 10 Hz ... 55 Hz | ||
| Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) | ||
| Weight: | 3,140 g | ||
- 上一產(chǎn)品:UE48-2OS2D2安全繼電器